Source removal is a straightforward principle applied carefully. Debris inside a duct is physically dislodged from the duct wall, and at the same moment the whole system is held under negative pressure so that loosened material travels one way only: into a filtered collection machine. Done properly, nothing is blown further down the line and nothing escapes into the room. Done poorly, with weak suction or the wrong tool, dust is simply redistributed, which can leave a system worse than it started even though the outlets look cleaner.
Our sequence is consistent. The extraction machine is connected at the plenum and allowed to establish negative pressure before any agitation starts. Outlets on the runs not being worked are sealed. Each run is then cleaned from the outlet back towards the plenum using rotary brushes for rigid duct or air whips and softer heads for flexible duct, at speeds set to protect the liner. We work one run at a time and confirm visually that it is clear before moving to the next, so progress is methodical rather than rushed.
Where the camera inspection showed heavy build-up or construction debris, we allow extra passes on those runs. Where a section is too damaged to clean safely, we stop, record it and explain why. The cleaning record notes which runs were done, how and with which tools, and anything left for follow-up. Before packing up, selected runs are re-filmed so you can compare them against the original inspection footage and see the difference for yourself.